Welcome to Shenzhen Donglaier Intelligent Technology Co.,Ltd website

Shenzhen Donglaier Intelligent Technology Co.,LtdWeChat QR code

Sweeping attention Donglaier smart WeChat QR code
Enjoy more information

Close

Terminal block module, relay module, optocoupler isolation module, signal isolation module, communication isolation module, communication I/O extension module, EtherCAT bus, CAN OPEN bus, RTX bus, Profinet NET bus, CC-LINK bus

Industrial automation total solution providerFocus on quick connect modules, bus modules, automation engineering

support hotline:+86-0755-29369330

24-hour hotline:15914121345

产品搜索

News

Contact Us

    Shenzhen Donglaier Intelligent Technology Co.,LTD
    Add:3/F, Building 108A, 7th Industrial Zone, Mashantou Community, Matian Street, Guangming District, Shenzhen.
    Tel:+86-0755-29369330
    Fax:+86-0755-29468353

    Mobile phone: 15914121345 Mr.Tan  (technical support)

                            15972616919 Mr. Li (business support)

    Contact person: Mr.Tan
    Email:yfdtzc@163.com
    Website:www.suncio.com
    taobao:https://shop107967679.taobao.com/
Location:Home > News > Industry news
The relay works in the case of insufficient voltage to solve the problem
Time:2018-07-12    Hits:503
Once the voltage applied to the coil is insufficient, the relay will not operate, or the operation will be unstable, which will cause the durability of the contact to decrease or the contact point such as welding to be blocked. In particular, in a large motor or the like, when the power is turned on, the voltage applied to the relay coil sometimes drops at the moment of a load operation in which a large inrush current is generated. If the relay is operated in a low voltage state, even if it is a vibration or shock value within the specifications specified in the specifications and catalogues, the relay may malfunction. Therefore, apply a rated voltage to the coil of the relay. For fluctuations in the power supply voltage, apply a voltage to the coil that each relay can fully operate. If a voltage is applied to the coil that does not allow the relay to fully operate, the coil will be abnormally heated, causing the coil to burn out. In addition, if a motor, a solenoid, a transformer, etc. are connected to the same power supply line as the operating circuit of the relay, when those devices operate, the power supply voltage is lowered, the contact of the relay is vibrated, causing the contact to burn out, welding, or Can not protect themselves. In particular, when a small transformer is used and when the transformer does not have a sufficient capacity, such a use method may occur if the wiring is long or the wiring for household use or shops is thin. If a similar fault occurs, use a synchronous oscilloscope to properly adjust the voltage change. Take appropriate countermeasures or convert to a DC circuit while taking countermeasures.